Skip to content
UniKit

Blind spot test

Run a real blind spot test from geometry: calibrate the screen with an ID card (85.6 mm), keep the fixation mark and the target on opposite sides, and drag the sliders for offset, target diameter and contrast in real time. Recording a vanished target converts the separation into a visual angle (the blind spot sits near 15°), and the record count, how many fall inside the range and the average angle all come from those real records. This is not a diagnosis.

Runs in your browserEvery computation happens in your browser — your data never leaves this device.

Hold an ID card or bank card against the screen and adjust the value until the box below matches its width (in pixels).

Distance from the fixation point to your eye, 15–120 cm. Measure it once; an error here shifts every angle.

78.99 mm
4 mm
100%
On-screen distance between the fixation mark and the target. Drag the slider or use the arrow keys and the picture is re-laid out from the calibration immediately. The dot is drawn from the calibration, so making it larger really makes it larger. Too small and you cannot see it, too large and it is no longer a target (0.5–50 mm). 100% is solid black; the lower it goes, the closer the dot is to the white background and the harder it is to see. This is a grey-level mapping, not a standard contrast measurement.Keyboard: left/right move 0.5 mm, R records, space starts or stops the sweep. Click the board once to give it focus.

Blind spot target area

Close one eye and stare at the + with the other: change the spacing slowly and watch where the dot vanishes. Click the board once, then fine-tune with the keyboard.

Fixation mark (stare here)15° · 78.99 mmTarget
When you stare at the fixation mark and the target disappears, press record and the current separation plus viewing distance is converted into a visual angle.

Measurement: 15° · inside the 12°–18° physiological blind spot range

Records (click one to jump back to that separation)

No record yet: press record or R when the target vanishes.

Right eye (close the left) · 30 cm away · offset 78.99 mm · 15°
Records
0
Inside the range
0
Last angle
—
Average angle
—
Target diameter
14.95 px (4 mm)
Pixels per mm
3.7383

Close one eye, stare at the + with the other and change the spacing slowly to see where the dot vanishes.

Test plan

Every number below comes from the geometry: θ = 2·arctan((separation/2)/viewing distance), and pixels merely map millimetres onto your screen.

Screen calibration: 85.6 mm = 320 px → 3.7383 px/mm (37.383 px/cm)
Viewing distance: 30 cm (right eye under test, close the left)
Fixation point: left side of the screen, target pattern on the right side (the blind spot lies on the temporal side)
Target offset: 78.99 mm = 295 px, i.e. 15° of visual angle (inside the 12°–18° physiological blind-spot range)
Sweep range: 41.96–116.63 mm (8°–22° of visual angle) = about 157–436 px
Physiology: the blind-spot centre is about 15° (roughly 12°–18° horizontally, less vertically) and varies a lot between people

Pixels per mm: 3.7383 · Viewing distance: 30 cm · Target offset: 78.99 mm · Target angle: 15° · Eye: Right eye (close the left) · Sweep range: 41.96–116.63 mm

Match the card width against this box

What this tool does

  • Reproduce the classic textbook experiment yourself: close one eye, stare at the fixation cross and let the dot on the other side drift until it disappears.
  • Turn the vanishing spacing into an angle: calibrate the screen with an ID or bank card (85.6 mm wide), then apply θ = 2·arctan((separation/2)/viewing distance).
  • Explain to students or family that the blind spot is normal anatomy: vanishing between 12° and 18° matches the physiological range the tool reports.
  • Adjust the target right on the page: the offset, diameter and contrast sliders re-lay out the fixation cross and the dot from the calibrated px/mm, so you can watch where the target vanishes.
  • Keep real records: press record (or R) when the target disappears and the current separation plus viewing distance is turned into an angle and stored; clicking any record moves the target back to that separation.

Example

Input

Reference width 320 px (≈85.6 mm ID card), viewing distance 30 cm, right eye under test, target angle 15°

Output

Screen calibration: 85.6 mm = 320 px → 3.7383 px/mm (37.383 px/cm)
Viewing distance: 30 cm (right eye under test, close the left)
Fixation point: left side of the screen, target pattern on the right side (the blind spot lies on the temporal side)
Target offset: 78.99 mm = 295 px, i.e. 15° of visual angle (inside the 12°–18° physiological blind-spot range)
Sweep range: 41.96–116.63 mm (8°–22° of visual angle) = about 157–436 px
Physiology: the blind-spot centre is about 15° (roughly 12°–18° horizontally, less vertically) and varies a lot between people

The 78.99 mm offset is simply the arc length for 15° at 30 cm: 2 × 30 × tan(7.5°) ≈ 7.9 cm.

Frequently asked questions

What is the blind spot and what does the test rely on?

Where the optic nerve leaves the eye (the optic disc) there are no photoreceptors, so each eye has an unseen region called the physiological blind spot. It sits about 15° temporally (right side for the right eye, left for the left), spanning roughly 12°–18° horizontally and less vertically. The test is the classic one: fixate a mark and move a target on the other side until it disappears.

How is the angle computed?

From the geometric definition of visual angle: θ = 2·arctan((separation / 2) / viewing distance). At 30 cm with a 7.9 cm separation, θ = 2·arctan(3.95/30) ≈ 15.2°. Pixels only place the marks on screen, which is why you first calibrate pixels per millimetre with an ID or bank card (85.6 mm wide, ISO/IEC 7810 ID-1).

Why does the vanishing point differ between runs?

Blind spot size and position vary between people and also shift with eye movement, pupil size, screen brightness and any error in estimating the viewing distance; uncorrected myopia or astigmatism makes it harder still. Measure a few times at 30–50 cm in moderate light and see whether the result stays inside 12°–18°.

Can I use the result as an eye examination?

No. It only shows that your blind spot lies roughly in this direction and at this angle; it cannot test visual acuity, visual field loss, glaucoma or macular disease. If the blind spot seems enlarged, or you notice a fixed dark patch or field loss, see a doctor — that is a different matter from the physiological blind spot.

Why is the fixation mark on the left by default?

Because the blind spot is temporal: testing the right eye (left eye closed) puts it on the right of your gaze, so the cross goes on the left and the target dot on the right. Switching to the left eye mirrors the layout and the tool also tells you which eye to close.

What do the three sliders control?

Offset is the on-screen separation between the fixation mark and the target (dragging it moves the dot sideways, and the arrow keys nudge it 0.5 mm at a time). Diameter is drawn from the calibration, so making it larger really makes it larger. Contrast fades the dot from solid black (100%) to nearly the white background (0%, practically invisible). All three only change what is drawn, never the geometry.

Does a record inside the range mean something is wrong with my eyes?

No. It only means the angle of that record falls inside the published 12°–18° physiological range, i.e. you reproduced the textbook experiment. It cannot diagnose anything and is not medical advice; a result that is too small or too large is more often caused by an estimation error in the viewing distance, screen brightness or not closing the other eye properly. See an eye doctor for any vision problem.

Keywords:blind spot testvisual angle

Related tools